IBM FS9500 4983-AH8 FlashSystem 9500 NVMe Storage System Upgrades Parts
IBM FlashSystem 9500 FS9500 4983-AH8 NVMe Enterprise Storage System
The IBM FlashSystem 9500 FS9500 4983-AH8 is a high-performance 4U enterprise NVMe storage platform designed for large databases, IBM Power Systems, IBM i, AIX, Linux, SAP, Oracle, VMware, analytics, virtualization and other business-critical workloads. The IBM FlashSystem 9500 system combines 48 internal NVMe drive slots, two active-active node canisters, IBM FlashCore Module technology, up to 3TB of system memory, high-speed Fibre Channel and Ethernet connectivity, and support for SAS-attached all-flash expansion enclosures. The IBM FlashSystem 9500 FS9500 includes models 4983-AH8 and 4666-AH8.
Use the IBM FlashSystem 9500 product page email price feature for custom configured IBM FS9500 pricing or inquire about 4983-AH8 upgrades and replacement parts. You may also use the IBM FlashSystem 9500 email price feature if you have general IBM FlashCore module compatibility questions for your IBM FS9500. All IBM Flash Storage, IBM FlashSystems, features and parts include warranty, support and are eligible for IBM maintenance. Download or view the IBM FS9500 Datasheet here.
IBM FS9500 FlashSystem 9500 NVMe Enterprise Storage System 4983-4H8 Performance Specifications and Maximums
The IBM FlashSystem 9500 4983-AH8 is designed as a high-performance enterprise storage platform for large databases, IBM Power Systems, virtualization, analytics and other business-critical workloads. Its architecture combines substantial controller processing power, up to 3TB of system memory, 48 internal NVMe drive slots, high-speed Fibre Channel and Ethernet connectivity, and support for additional SAS-attached all-flash expansion capacity.
IBM states the FS9500 performance can reache approximately 2.5 million 4K read-miss IOPS per control enclosure, read latency of less than approximately 50 microseconds under qualifying conditions, and read bandwidth of up to approximately 45GB/s per control enclosure. These FlashSystem 9500 peformance statistics should be considered maximum capabilities rather than guaranteed application performance. Actual results depend on block size, read/write ratio, FlashCore Module configuration, RAID design, system memory, host connectivity, queue depth, data reduction and IBM Storage Virtualize software level.
| Performance / Maximum Characteristic | IBM FlashSystem 9500 4983-AH8 Specification |
|---|---|
| Maximum IOPS | Up to approximately 2.5 million 4K read-miss IOPS per control enclosure |
| Minimum Published Read Latency | Less than approximately 50 microseconds under qualifying conditions |
| Maximum Read Bandwidth | Up to approximately 45GB/s per control enclosure |
| Control Enclosure | 4U |
| Processors | 4 Intel Xeon processors total, 24 cores each |
| Total Processor Cores | 96 cores per control enclosure |
| Node Canisters | 2 active-active node canisters per control enclosure |
| Base System Memory | Approximately 1TB |
| Maximum System Memory | Approximately 3TB per control enclosure |
| Maximum Memory per Node | Approximately 1.5TB |
| Internal NVMe Drive Slots | 48 per control enclosure |
| Maximum Control Enclosures per System | 2 |
| Maximum Active Nodes | 4 |
| Maximum Internal NVMe Drives | 96 with two control enclosures |
| Largest FCM3 / FCM4 Capacity | 38.4TB per FlashCore Module |
| Maximum Nominal Internal FCM Capacity – One Enclosure | 1,843.2TB using 48 × 38.4TB FCMs |
| Maximum Nominal Internal FCM Capacity – Two Enclosures | 3,686.4TB using 96 × 38.4TB FCMs |
| Maximum Total Drives | Up to 464 at applicable IBM Storage Virtualize levels |
| Maximum Expansion Enclosures | Up to 12 per two-control-enclosure system at applicable software levels |
| Maximum Fibre Channel Hosts | 2,048 |
| Maximum Volume Mappings per Host | 2,048 |
| Maximum Host Mappings per System | 64,000 |
| Maximum NVMe/RDMA Hosts | Up to 512 per system at applicable software levels |
| Maximum NVMe/TCP Hosts | Up to 512 per system at applicable software levels |
| Maximum Managed Storage | Up to 32PB |
| Maximum Individual Volume | 256TB |
| Maximum Fibre Channel Speed | 64Gb Fibre Channel |
| Maximum Ethernet Speed | 100Gb Ethernet |
| Maximum Remote Copy Relationships | Up to 10,000 |
| Maximum HyperSwap Relationships | Up to 2,000 |
FlashSystem 9500 Controller and Processor Performance
The IBM FS9500 provides considerably more controller processing capacity than smaller FlashSystem platforms. A single control enclosure contains four Intel Xeon processors with 24 processor cores each, providing a total of approximately 96 processor cores across the two active-active node canisters. The FS9500 processors support the storage system's core functions, including:
- Storage virtualization
- Cache management
- Distributed RAID processing
- Host I/O processing
- Replication
- Data reduction services
- Snapshots and cloning
- Encryption
- External storage virtualization
- Storage management and monitoring
This processing capacity is particularly important in highly consolidated environments where the storage system must simultaneously support thousands of hosts, large numbers of volumes, multiple host protocols and intensive data services.
FlashSystem 9500 Memory and Cache Performance
The 4983-AH8 can be configured with approximately 1TB, 2TB or 3TB of total system memory. At the maximum configuration, each node canister contains approximately 1.5TB of memory.
| Memory Configuration | Feature Code | Memory per Node | Total System Memory |
|---|---|---|---|
| Base | ACGM | Approximately 512GB | Approximately 1TB |
| Cache Upgrade | ACGN | Approximately 1TB | Approximately 2TB |
| Maximum Cache Configuration | ACGP | Approximately 1.5TB | Approximately 3TB |
IBM recommends larger memory configurations for workloads that make intensive use of cache, Data Reduction Pools, deduplication or large numbers of drives and host connections. System memory can therefore be an important performance consideration even when the installed FlashCore Modules remain unchanged.
48 Internal NVMe Drive Slots
A single FlashSystem 9500 control enclosure provides 48 front-accessible NVMe drive positions, giving the platform substantially greater internal flash density than smaller FlashSystem systems.
The internal NVMe storage can include supported:
- FlashCore Module 3
- FlashCore Module 4
- Industry-standard NVMe SSDs
- NVMe Storage Class Memory
A standard two-control-enclosure FlashSystem 9500 system can therefore contain as many as 2 control enclosures × 48 NVMe slots = 96 internal NVMe devices.
Maximum Internal FlashCore Capacity
The largest supported FCM3 and FCM4 capacity is 38.4TB per FlashCore Module. A single FlashSystem 9500 enclosure populated with 48 × 38.4TB modules provides 48 × 38.4TB = 1,843.2TB ≈ 1.84PB nominal installed flash capacity. A two-control-enclosure configuration provides 96 × 38.4TB = 3,686.4TB ≈ 3.69PB nominal installed flash capacity.
FCM4 Performance Characteristics
FlashCore Module 4 capacity influences both storage density and individual-module performance. IBM publishes higher bandwidth and IOPS for the larger 19.2TB and 38.4TB modules than for the 4.8TB and 9.6TB models.
| FCM4 Capacity | Approx. Read Bandwidth | Approx. Write Bandwidth | Approx. 16K Read IOPS | Endurance |
|---|---|---|---|---|
| 4.8TB | Up to approximately 2,200MB/s | Up to approximately 750MB/s | Approximately 150K | 1 DWPD |
| 9.6TB | Up to approximately 2,200MB/s | Up to approximately 750MB/s | Approximately 150K | 1 DWPD |
| 19.2TB | Up to approximately 3,500MB/s | Up to approximately 1,500MB/s | Approximately 200K | 1 DWPD |
| 38.4TB | Up to approximately 3,500MB/s | Up to approximately 1,500MB/s | Approximately 200K | 1 DWPD |
High-Speed Fibre Channel Connectivity
The FlashSystem 9500 supports high-speed Fibre Channel connectivity for traditional SCSI-based SAN environments and NVMe over Fibre Channel.
Supported configurations include:
- 32Gb Fibre Channel
- 64Gb Fibre Channel
- FC-NVMe / NVMe over Fibre Channel
At applicable configuration levels, a single control enclosure can provide substantial aggregate Fibre Channel connectivity, allowing the system to support large numbers of hosts while maintaining multiple redundant paths. A high-performance storage array can still become constrained if insufficient host-side bandwidth is provided. SAN design, HBA speed, switch capacity, zoning, multipathing and host queue depth should therefore be considered when sizing the FlashSystem 9500.
100Gb Ethernet and NVMe over Fabrics
The FlashSystem 9500 also supports Ethernet host connectivity reaching 100Gb. Supported Ethernet-based storage and communication capabilities can include:
- iSCSI
- NVMe/TCP
- NVMe/RDMA
- Storage replication
- High-availability communication
- Inter-system communication
Ethernet and Fibre Channel adapters can be combined within supported configuration rules to accommodate heterogeneous host environments.
Enterprise Host Scale
The FlashSystem 9500 is designed to support highly consolidated enterprise storage environments. At applicable IBM Storage Virtualize levels, important host-scale limits include:
| Host Scale Characteristic | Maximum |
|---|---|
| Hosts per system | 2,048 |
| Volume mappings per host | 2,048 |
| Total host mappings | 64,000 |
| NVMe/RDMA hosts per system | Up to approximately 512 |
| NVMe/TCP hosts per system | Up to approximately 512 |
This scale makes the 9500 well suited to highly consolidated VMware estates, IBM Power Systems environments, database infrastructures and mixed enterprise workloads.
Storage Virtualize Scale
The IBM Storage Virtualize software architecture allows the FlashSystem 9500 to manage substantially more storage than the capacity physically installed in its internal NVMe slots.
| Storage Virtualize Scale Characteristic | Maximum at Applicable Software Levels |
|---|---|
| Managed disks | 4,096 |
| Storage pools | 1,024 |
| Total managed storage | Up to 32PB |
| Maximum individual volume | 256TB |
| Remote Copy relationships | Up to 10,000 |
| HyperSwap relationships | Up to 2,000 |
| Data Reduction Pools | Up to 4 |
Expansion Performance and Capacity
The FlashSystem 9500 supports SAS-attached all-flash expansion storage in addition to the internal NVMe tier. At applicable IBM Storage Virtualize levels, a two-control-enclosure system can support:
- Up to 12 expansion enclosures
- Up to 464 total drives
- Up to 232 drives per I/O Group
- Two SAS expansion chains per control enclosure
The internal NVMe FlashCore tier should be distinguished from SAS-attached expansion media when evaluating performance. NVMe FCM3 and FCM4 storage provides the lowest-latency path, while SAS-attached flash expansion provides additional capacity and tiering flexibility.
Scale-Out with Two FlashSystem 9500 Control Enclosures
A FlashSystem 9500 can scale beyond a single 4U controller enclosure by adding a second supported 4983-AH8 control enclosure. A two-enclosure system provides:
- 4 active node canisters
- 96 internal NVMe slots
- Additional controller processing capacity
- Additional host connectivity
- Additional cache resources
- Additional SAS expansion capability
This scale-out architecture is one of the key differences between the 9500 and smaller FlashSystem platforms.
FlashSystem 9500 Performance at a Glance
Important FlashSystem 9500 Performance Considerations
Peak performance specifications are useful for comparing storage platforms, but application performance depends on the complete storage path and workload profile. Important considerations include:
- Block Size: Small-block workloads emphasize IOPS, while larger sequential I/O emphasizes bandwidth.
- Read / Write Ratio: Read-intensive and write-intensive workloads behave differently.
- FCM Capacity: Larger FCM4 capacities provide higher per-module performance in addition to increased capacity.
- Drive Count: Additional FlashCore Modules can increase parallelism and aggregate performance.
- Cache Configuration: Cache-heavy environments can benefit from the 2TB or 3TB memory configurations.
- Distributed RAID: RAID design affects usable capacity, write behavior, resilience and rebuild performance.
- Host Connectivity: Insufficient Fibre Channel or Ethernet bandwidth can prevent applications from using available storage performance.
- SAN Design: Switch oversubscription, zoning and path design can affect throughput and latency.
- Host Configuration: Multipathing, HBA capabilities and queue depth can significantly influence realized performance.
- Data Reduction: Compression and deduplication results vary according to workload characteristics.
- Software Level: IBM Storage Virtualize releases can change performance characteristics, supported hardware and configuration maximums.
IBM FlashSystem 9500 4983-AH8 Overview
| IBM Product | IBM Storage FlashSystem 9500 |
|---|---|
| Machine Type / Model | 4983-AH8 |
| Form Factor | 4U rack-mounted NVMe control enclosure |
| Node Canisters | 2 active-active node canisters |
| Processors | Two 24-core processors per node canister |
| Internal NVMe Slots | 48 |
| FlashCore Generations | IBM FlashCore Module 3 and FlashCore Module 4 |
| Maximum FCM Capacity | 38.4TB per module |
| Industry-Standard NVMe | 1.92TB through 30.72TB |
| Storage Class Memory | 1.6TB NVMe SCM |
| Base System Memory | 1TB total |
| Maximum System Memory | Approximately 3TB total |
| Fibre Channel | 32Gb and 64Gb FC / FC-NVMe |
| Ethernet | 25Gb and 100Gb Ethernet |
| SAS Expansion | 12Gb SAS |
| Expansion Enclosures | 4983-AFF and 4983-A9F |
| Storage Software | IBM Storage Virtualize |
IBM FlashSystem 9500 Performance and Maximum Specifications
The FlashSystem 9500 is designed as a high-end enterprise storage platform where performance, capacity and scale are all important. Its architecture provides 48 internal NVMe devices in a single 4U enclosure, significantly more internal media than smaller FlashSystem platforms.
| Maximum / Performance Characteristic | IBM FlashSystem 9500 Specification |
|---|---|
| Control Enclosure | 4U |
| Internal NVMe Slots | 48 |
| Maximum NVMe Drives – Two-Enclosure System | 96 |
| Node Canisters | 2 per control enclosure |
| Maximum Control Enclosures per System | 2 under standard supported configuration |
| Maximum Active Nodes | 4 |
| Maximum System Memory per Enclosure | Approximately 3TB |
| Maximum Internal FCM Capacity | 48 × 38.4TB = 1,843.2TB nominal |
| Maximum Usable Capacity – One Control Enclosure | Approximately 1,834TB using IBM's documented DRAID6 configuration |
| Maximum Effective Capacity – One Control Enclosure | Up to approximately 9.216PB using IBM's stated 5:1 software data-reduction assumption |
| Maximum Effective Capacity – Two Control Enclosures | Up to approximately 18.432PB under IBM's stated assumptions |
| Maximum Fibre Channel Speed | 64Gb FC |
| Maximum Ethernet Speed | 100Gb Ethernet |
| Maximum 32Gb FC Ports – One Enclosure | 48 |
| Maximum 64Gb FC Ports – One Enclosure | 24 |
| Maximum 100Gb Ethernet Ports – One Enclosure | 12 |
| Maximum Drives per System | 464 at applicable Storage Virtualize levels |
| Maximum Expansion Enclosures per System | 12 at applicable Storage Virtualize levels |
| Maximum Managed Storage | Up to 32PB at applicable Storage Virtualize levels and extent sizes |
Maximum Internal FlashCore Capacity
A single FlashSystem 9500 control enclosure contains 48 NVMe slots. Using 48 of the largest 38.4TB FlashCore Modules provides 48 × 38.4TB = 1,843.2TB ≈ 1.84PB nominal installed flash capacity. IBM states approximately 1,834TB of maximum usable capacity for a 48-drive DRAID6 configuration before additional data reduction is considered. A two-control-enclosure FlashSystem 9500 system can therefore provide up to 96 internal NVMe devices.
IBM FlashSystem 9500 Feature Code Quick Reference
| Category | Description | Feature Code / Model | IBM Ordering Identifier |
|---|---|---|---|
| Control Enclosure | FlashSystem 9500 with Expert Care | AH8 | 4983-AH8 |
| Expansion | 2U24 All-Flash Expansion with Expert Care | AFF | 4983-AFF |
| Expansion | 5U92 All-Flash Expansion with Expert Care | A9F | 4983-A9F |
| Memory | 1TB Base Cache / Memory | ACGM | 4983-ACGM |
| Memory | 1TB Cache Upgrade | ACGN | 4983-ACGN |
| Memory | Additional 1TB Cache Upgrade | ACGP | 4983-ACGP |
| Boot Storage | 480GB M.2 Boot Drive Pair | ACGU | 4983-ACGU |
| Fibre Channel | 32Gb FC 4-Port Adapter Pair | AHBB | 4983-AHBB |
| Fibre Channel | 64Gb FC 4-Port Adapter Pair | AHBK | 4983-AHBK |
| Ethernet | 100Gb Ethernet RoCE Adapter Pair | AHB8 | 4983-AHB8 |
| Ethernet | 10/25Gb Ethernet RoCE Adapter Pair | AHBH | 4983-AHBH |
| Ethernet | 10/25Gb Ethernet iWARP Adapter Pair | AHBJ | 4983-AHBJ |
| SAS Expansion | 12Gb SAS Expansion Enclosure Attach Card Pair | AHBA | 4983-AHBA |
| FCM3 | 4.8TB FlashCore Module 3 | AHS9 | 4983-AHS9 |
| FCM3 | 9.6TB FlashCore Module 3 | AHSA | 4983-AHSA |
| FCM3 | 19.2TB FlashCore Module 3 | AHSB | 4983-AHSB |
| FCM3 | 38.4TB FlashCore Module 3 | AHSC | 4983-AHSC |
| FCM4 | 4.8TB FlashCore Module 4 | AHSE | 4983-AHSE |
| FCM4 | 9.6TB FlashCore Module 4 | AHSF | 4983-AHSF |
| FCM4 | 19.2TB FlashCore Module 4 | AHSG | 4983-AHSG |
| FCM4 | 38.4TB FlashCore Module 4 | AHSH | 4983-AHSH |
| NVMe SSD | 1.92TB Industry-Standard NVMe SSD | AHTH | 4983-AHTH |
| NVMe SSD | 3.84TB Industry-Standard NVMe SSD | AHTI | 4983-AHTI |
| NVMe SSD | 7.68TB Industry-Standard NVMe SSD | AHTJ | 4983-AHTJ |
| NVMe SSD | 15.36TB Industry-Standard NVMe SSD | AHTK | 4983-AHTK |
| NVMe SSD | 30.72TB Industry-Standard NVMe SSD | AHTL | 4983-AHTL |
| SCM | 1.6TB NVMe Storage Class Memory | AHTM | 4983-AHTM |
IBM FlashSystem 9500 Cache and Memory Upgrades
The FlashSystem 9500 provides significantly more memory and cache scalability than smaller FlashSystem models. Each node canister supports as many as twenty-four 64GB DIMMs.
| Configuration | Feature Code | Memory per Node | Total System Memory | Typical Use |
|---|---|---|---|---|
| Base | ACGM | 512GB | 1TB | Base configurations and moderate I/O workloads |
| Upgrade 1 | ACGN | 1,024GB | 2TB | Cache-heavy I/O, DRP and deduplication workloads |
| Upgrade 2 | ACGP | 1,536GB | Approximately 3TB | Maximum cache-heavy and high-I/O configurations |
IBM specifically recommends the larger memory configurations for cache-heavy workloads, Data Reduction Pools, deduplication and systems with larger numbers of installed drives and host adapters.
IBM FlashSystem 9500 FlashCore Module 3 – FCM3
FlashCore Module 3 uses NVMe storage with IBM hardware-assisted compression, self-encryption and T10-DIF data-integrity protection.
| Capacity | Feature Code | Ordering Identifier | Known Service FRU |
|---|---|---|---|
| 4.8TB | AHS9 | 4983-AHS9 | 03JK076 |
| 9.6TB | AHSA | 4983-AHSA | 03JK077 |
| 19.2TB | AHSB | 4983-AHSB | Verify installed FRU revision |
| 38.4TB | AHSC | 4983-AHSC | Verify installed FRU revision |
IBM FlashSystem 9500 FlashCore Module 4 – FCM4
FlashCore Module 4 adds computational-storage capabilities to the FlashCore architecture while retaining hardware-based compression, self-encryption and enterprise NVMe performance.
| Capacity | Feature Code | Ordering Identifier | Example IBM Service FRU |
|---|---|---|---|
| 4.8TB | AHSE | 4983-AHSE | 03JK992 |
| 9.6TB | AHSF | 4983-AHSF | 03LG001 |
| 19.2TB | AHSG | 4983-AHSG | 03LG010 |
| 38.4TB | AHSH | 4983-AHSH | 03LG019 |
FCM3 and FCM4 Compatibility
The FlashSystem 9500 supports both FCM3 and FCM4. IBM Storage Virtualize can support an intermix of supported internal storage technologies, although drives within an individual array should use the appropriate matching drive technology and capacity. When planning an FCM4 deployment specifically for computational-storage-assisted ransomware detection, configure the applicable RAID array entirely with FCM4 media.
Industry-Standard NVMe Flash Drives
The FlashSystem 9500 also supports industry-standard self-encrypting NVMe SSDs. These drives provide enterprise NVMe performance, hardware-based data-at-rest encryption and T10-DIF protection but do not include the internal compression and computational-storage functions of IBM FlashCore Modules.
| Capacity | Feature Code | Ordering Identifier |
|---|---|---|
| 1.92TB | AHTH | 4983-AHTH |
| 3.84TB | AHTI | 4983-AHTI |
| 7.68TB | AHTJ | 4983-AHTJ |
| 15.36TB | AHTK | 4983-AHTK |
| 30.72TB | AHTL | 4983-AHTL |
1.6TB NVMe Storage Class Memory
| Capacity | 1.6TB |
|---|---|
| Feature Code | AHTM |
| Ordering Identifier | 4983-AHTM |
| Technology | NVMe Storage Class Memory |
| Maximum SCM Drives per I/O Group | 12 |
Storage Class Memory is intended for particularly latency-sensitive, relatively small-capacity workloads and can coexist with supported FlashCore and NVMe storage within the system.
IBM FlashSystem 9500 Fibre Channel Connectivity
AHBB – 32Gb Fibre Channel Adapter Pair
| Feature Code | AHBB |
|---|---|
| Ordering Identifier | 4983-AHBB |
| Adapters | 2 |
| Ports per Adapter | 4 |
| Interface | 32Gb Fibre Channel |
| Protocols | SCSI over FC and FC-NVMe |
| Standard Optics | Short-wave SFP transceivers |
AHBK – 64Gb Fibre Channel Adapter Pair
| Feature Code | AHBK |
|---|---|
| Ordering Identifier | 4983-AHBK |
| Adapters | 2 |
| Ports per Adapter | 4 |
| Interface | 64Gb Fibre Channel |
| Protocols | SCSI over FC and FC-NVMe |
IBM FlashSystem 9500 Ethernet Connectivity
| Feature Code | Description | Ordering Identifier | Ports per Adapter |
|---|---|---|---|
| AHB8 | 100Gb Ethernet RoCE Adapter Pair | 4983-AHB8 | 2 × 100Gb |
| AHBH | 10/25Gb Ethernet RoCE Adapter Pair | 4983-AHBH | 2 × 25Gb |
| AHBJ | 10/25Gb Ethernet iWARP Adapter Pair | 4983-AHBJ | 2 × 25Gb |
Depending upon adapter and Storage Virtualize configuration, Ethernet interfaces can support iSCSI, NVMe/TCP, RDMA, replication and high-availability communications.
IBM FlashSystem 9500 Transceivers and Optics
| Feature | Description | Requires |
|---|---|---|
| ACHP | Four 25Gb Ethernet short-wave SFP28 transceivers | AHBH, AHBJ or applicable adapter |
| ACHQ | Four 10Gb Ethernet short-wave SFP+ transceivers | AHBH, AHBJ or applicable adapter |
| ACHV | Pair of 32Gb Fibre Channel long-wave SFP transceivers | AHBB |
| ACHX | Four 100Gb Ethernet QSFP28 SR4 transceivers | AHB8 |
IBM FlashSystem 9500 Fibre Channel Cables
| Feature Code | Description |
|---|---|
| ACSQ | 1m OM3 Fibre Cable – LC |
| ACSU | 2m OM3 Fibre Cable – LC |
| ACSR | 5m OM3 Fibre Cable – LC |
| ACSS | 10m OM3 Fibre Cable – LC |
| ACST | 25m OM3 Fibre Cable – LC |
IBM FlashSystem 9500 Expansion Enclosures
Unlike systems designed exclusively around internal NVMe storage, the FlashSystem 9500 can scale capacity through 12Gb SAS-attached all-flash expansion enclosures.
| IBM Model | Description | Drive Bays | Form Factor | Interface |
|---|---|---|---|---|
| 4983-AFF | FlashSystem 9500 SFF All-Flash Expansion with Expert Care | 24 | 2U | 12Gb SAS |
| 4983-A9F | FlashSystem 9500 High-Density All-Flash Expansion with Expert Care | 92 | 5U | 12Gb SAS |
AHBA SAS Expansion Enclosure Attach Card
| Feature Code | AHBA |
|---|---|
| Ordering Identifier | 4983-AHBA |
| Description | 12Gb SAS Expansion Enclosure Attach Card Pair |
| Adapters | 2 |
| Purpose | Connects supported AFF or A9F SAS expansion enclosures |
Expansion Enclosure Configuration Limits
IBM uses SAS-chain weighting rules for the FlashSystem 9500:
- Up to three 2U24 AFF enclosures per SAS chain
- Up to one 5U92 A9F enclosure per SAS chain
- Two SAS chains are supported per control enclosure
- FCM3 and FCM4 modules are installed in the NVMe control enclosure, not the SAS expansion enclosures
IBM FlashSystem 9500 SAS Expansion Cables
| Feature Code | Description |
|---|---|
| ACUA | 0.6m 12Gb SAS Cable – SFF Expansion |
| ACUB | 1.5m 12Gb SAS Cable – SFF Expansion |
| ACUC | 3m 12Gb SAS Cable – SFF / High-Density Expansion |
| ACUD | 6m 12Gb SAS Cable – SFF / High-Density Expansion |
Expansion Enclosure SAS SSD Capacities
The 4983-AFF and 4983-A9F expansion enclosures support IBM-qualified SAS flash storage. Supported capacities include:
- 1.92TB SAS SSD
- 3.84TB SAS SSD
- 7.68TB SAS SSD
- 15.36TB SAS SSD
- 30.72TB SAS SSD
The 4983-AFF supports up to 24 flash drives, while the high-density 4983-A9F supports up to 92 flash drives.
IBM FlashSystem 9500 Encryption Features
| Feature Code | Description |
|---|---|
| ACEE | Encryption Enablement |
| ACEA | Encryption USB Flash Drives – Four Pack |
FlashSystem 9500 supports AES-XTS 256-bit data-at-rest encryption. Encryption keys can be managed using supported USB flash drives or external key-management configurations.
Other Important FlashSystem 9500 Features
| Feature Code | Description |
|---|---|
| ACGU | 480GB M.2 Boot Drive Pair |
| AHY2 | Remote Code Load support with applicable Expert Care configuration |
| ADN1 | Order Type 1 Indicator – CTO |
| ALH0 | IBM Storage Expert Care Indicator |
IBM FlashSystem 9500 Active-Active Architecture
Each FlashSystem 9500 control enclosure contains two active-active node canisters that form an IBM Storage Virtualize I/O Group. Both node canisters participate in serving storage during normal operation. If one node canister fails or is taken offline for supported service operations, storage access can continue through the partner node. The control enclosure also contains four redundant power supplies and can remain powered using any two supplies, providing N+2 power redundancy.
FlashSystem 9500 Scale-Out Architecture
A standard FlashSystem 9500 system can contain up to two 4983-AH8 control enclosures, creating two I/O Groups and four active node canisters. This increases internal NVMe capacity to as many as 2 control enclosures × 48 NVMe slots = 96 NVMe devices. The IBM FS9500 also supports SAS expansion enclosures for additional flash capacity.
IBM Storage Virtualize Features
IBM Storage Virtualize provides the software foundation of the FlashSystem 9500 and includes enterprise storage functions such as:
- Distributed RAID
- Thin provisioning
- FlashCore hardware compression
- Data Reduction Pools
- Deduplication
- Encryption
- Easy Tier
- Snapshots
- Cloning
- Replication
- Policy-based replication
- High availability
- Safeguarded Copy / Safeguarded Snapshot capabilities
- External storage virtualization
- REST API automation
- Ansible integration
- VMware integration
- Container Storage Interface integration
- Ransomware threat detection
IBM FlashSystem 9500 Upgrade and Replacement Planning
Before ordering a replacement part, capacity expansion or connectivity upgrade for a 4983-AH8, verify:
- Machine type and model 4983-AH8
- Machine serial number
- Installed IBM Storage Virtualize level
- Installed FCM generation
- Drive capacity and feature code
- Physical service FRU
- Existing Distributed RAID configuration
- Available NVMe slots
- Installed memory configuration
- Available PCIe adapter slots
- Adapter symmetry between node canisters
- Required SFPs and cables
- Expansion enclosure type and SAS-chain configuration
IBM FlashSystem 9500 Feature Codes vs. FRU Part Numbers
| Identifier | Example | Purpose |
|---|---|---|
| Machine Type / Model | 4983-AH8 | Identifies the FlashSystem 9500 control enclosure |
| Feature Code | AHSH | Identifies a configurable IBM feature, such as the 38.4TB FCM4 |
| Ordering Identifier | 4983-AHSH | Machine type plus configurable feature |
| Service FRU | 03LG019 | Identifies a physical service replacement component or hardware revision |
IBM FlashSystem 9500 Frequently Asked Questions
What is the IBM machine type for FlashSystem 9500 with Expert Care?
The IBM Storage FlashSystem 9500 with Expert Care is machine type and model 4983-AH8.
How many NVMe drives does a FlashSystem 9500 support?
Each 4U control enclosure provides 48 front-accessible NVMe slots. A standard two-control-enclosure system can therefore contain up to 96 internal NVMe devices.
Which FlashCore Modules does the 4983-AH8 support?
The FlashSystem 9500 supports FCM3 and FCM4 in 4.8TB, 9.6TB, 19.2TB and 38.4TB capacities.
What is the feature code for a 38.4TB FCM4?
The FlashSystem 9500 feature code for the 38.4TB FCM4 is AHSH.
What is the feature code for a 19.2TB FCM4?
The 19.2TB FCM4 uses feature code AHSG.
What is the maximum FlashSystem 9500 memory?
A control enclosure supports approximately 3TB of total system memory, or 1.5TB per node canister.
Does FlashSystem 9500 support 64Gb Fibre Channel?
Yes. Feature AHBK provides a pair of four-port 64Gb Fibre Channel adapters.
Does FlashSystem 9500 support 100Gb Ethernet?
Yes. Feature AHB8 provides a pair of dual-port 100Gb Ethernet RoCE adapters.
Can the FlashSystem 9500 use expansion enclosures?
Yes. The 4983-AH8 supports the 4983-AFF 2U24 and 4983-A9F 5U92 all-flash SAS expansion enclosures.
What adapter is required for FlashSystem 9500 expansion enclosures?
Feature AHBA provides the 12Gb SAS Expansion Enclosure Attach Card pair.
Does FlashSystem 9500 support standard NVMe SSDs?
Yes. Supported capacities include 1.92TB, 3.84TB, 7.68TB, 15.36TB and 30.72TB.
Does FlashSystem 9500 support Storage Class Memory?
Yes. Feature AHTM provides a 1.6TB NVMe Storage Class Memory drive.
Can FlashSystem 9500 use FCM3 and FCM4?
Yes. The platform supports both generations. For FCM4 computational-storage-assisted ransomware detection, the applicable array must be constructed entirely from FCM4 modules and meet IBM's software-level requirements.