Model Number: IBM-AHSA-FCM3
Call for Price: (888) 682-5335

IBM AHSA 9.6TB NVMe FlashCore Module 3 FCM3

Feature Code AHSA | 9.6TB NVMe FlashCore Module 3 for IBM FlashSystem 7300 | Part Numbers 03JK077 03JK693 03GH933 03JK163 03LG627 03LG623 03JK159

The IBM AHSA 9.6TB NVMe FlashCore Module 3 FCM3 is a third-generation IBM FlashCore storage module designed for an IBM FlashSystem 9500 FS9500 Model 4666-AH8 4983-AH8 and 4666-UH8 control enclosure. IBM FlashCore Module 3 combines enterprise NVMe flash storage with hardware-based inline compression, self-encryption, advanced flash management, data-integrity protection, and tight integration with IBM Storage Virtualize. Unlike conventional enterprise NVMe SSDs, IBM FlashCore Modules incorporate IBM-developed hardware and firmware optimized specifically for FlashSystem environments. This architecture enables high throughput, predictable low latency, hardware-assisted data reduction, and enterprise-class reliability while minimizing processing overhead on the FlashSystem controllers. The AHSA feature code identifies the 9.6TB FCM3 for an IBM FlashSystem 9500 FS9500 Model 4666-AH8 4983-AH8 and 4666-UH8 control enclosures, and may have 03JK077 03JK693 03GH933 03JK163 03LG627 03LG623 and 03JK159 part numbers.

The IBM AGSB is for an IBM FlashSystem 5200 FS5200 Model 4662-6H2 and 4662-UH6 control enclosure, and the IBM ADSB 9.6TB NVMe FlashCore Module 3 FCM3 is for an IBM FlashSystem 7300 FS7300 Model 4657-924 and 4657-U7D control enclosures. See the FCM Features tab to view other FlashCore Modules supported by each IBM FlashSystem model, as well as their corresponding part numbers and feature codes. Use the email price feature from on this product page for IBM AHSA 9.6TB NVMe FlashCore Module FCM3 pricing, to request an IBM FlashSystem upgrade quote, or if you have general IBM FlashCore module compatibility questions for your specific FlashSystem model. All IBM FlashSystems, FlashCore Modules and parts include warranty, support and are eligibile for IBM maintenance..

IBM AHSA 9.6TB FCM3 Key Features

  • IBM Feature Code: ADSB
  • FlashCore Generation: FlashCore Module 3 (FCM3)
  • Capacity: 9.6TB
  • IBM Part Numbers: 03JK077 03JK693 03GH933 03JK163 03LG627 03LG623 and 03JK159
  • Enterprise NVMe storage architecture
  • Hardware-based inline data compression
  • Self-encrypting FlashCore technology
  • Hardware-based data-at-rest protection
  • T10-DIF data-integrity protection
  • IBM advanced flash management
  • Enterprise-class endurance and reliability
  • Designed for IBM Storage Virtualize environments
  • Compatible with FCM4 replacement and expansion scenarios on supported systems

AHSA Technical Specifications

IBM Feature Code AHSA
FlashCore Generation FlashCore Module 3 (FCM3)
Capacity 9.6TB
IBM Part Numbers 03JK077 03JK693 03GH933 03JK163 03LG627 03LG623 03JK159
Storage Interface NVMe
Compression Hardware-based inline compression
Encryption Self-encrypting FlashCore technology
Data Integrity T10-DIF support
Computational Storage No — introduced with FCM4
FCM4 Compatibility FCM4 may be used as a replacement, array extension, MES upgrade, or additional storage on supported FCM3 systems

IBM FlashSystem Compatibility

The AHSA feature code is associated with the 9.6TB FlashCore Module 3 for the IBM FlashSystem 7300. The same 9.6TB FCM3 technology is also used in other FCM3-supporting FlashSystem platforms under different machine-specific feature codes.

IBM FlashSystem ModelFCM3 Support9.6TB FCM3 Feature Code
IBM FlashSystem 5200 Supported AGSB
IBM FlashSystem 7300 Supported ADSB
IBM FlashSystem 9500 Supported AHSA
Technical Note: IBM FlashCore feature codes are machine-specific. ADSB identifies the 9.6TB FCM3 when ordered for a FlashSystem 7300. A corresponding 9.6TB FCM3 installed in another FlashSystem family may use a different feature code even when the underlying FlashCore generation and capacity are equivalent.

FlashCore Module 3 Capacity Options

FlashSystem 9500 Feature CodeCapacityPart Numbers and FRUs
IBM AHS9 4.8TB 03JK076 03JK162 03GH935 03GH936 03JK687
IBM AHSA 9.6TB 03JK077 03JK693 03GH933 03JK163 03LG627 03LG623 03JK159
IBM AHSB 19.2TB 03JK078 03GH931 03GH932 03JK160 03JK164 03JK699
IBM AHSC 38.4TB 03JK079 03JK165

FCM3 and FCM4 Compatibility

IBM FlashCore Module 4 was designed as a compatible replacement and expansion path for FlashCore Module 3. On supported FlashSystem 5200, 7300, and 9500 systems, FCM4 modules can be used to replace FCM3 modules, extend an existing FCM3 RAID array, provide additional storage, or be introduced as part of an MES upgrade.

This compatibility allows an existing FCM3 environment to continue operating while FCM4 capacity is introduced without requiring all FCM3 modules in the system to be replaced at the same time.

Can FCM3 and FCM4 Be Mixed in the Same FlashSystem?

Yes. FCM3 and FCM4 can coexist within supported IBM FlashSystem 5200, 7300, and 9500 systems.

Supported use cases include:

  • Maintaining existing FCM3 arrays while adding new FCM4 storage.
  • Replacing an FCM3 module with an FCM4 service replacement where supported.
  • Using FCM4 modules to extend an existing FCM3 RAID array.
  • Creating dedicated all-FCM4 arrays alongside existing FCM3 arrays.

Can FCM3 and FCM4 Be Mixed in the Same RAID Array?

Yes. FCM4 can be used within an existing FCM3 RAID array, including as a replacement for an FCM3 module or as an extension of an existing supported array.

There is an important functional distinction when the generations are mixed:

Important: An FCM4 installed in the same RAID array as FCM3 modules operates with FCM3-level functionality. FCM4-specific Computational Storage features are therefore not available to the mixed FCM3/FCM4 array.

To take advantage of FCM4-specific Computational Storage capabilities, administrators should create an array composed entirely of FCM4 modules and meet the applicable IBM Storage Virtualize requirements.

FCM3 / FCM4 Compatibility Summary

ConfigurationSupportedOperational Consideration
FCM3 and FCM4 in the same FlashSystem Yes Supported on applicable FlashSystem 5200, 7300, and 9500 systems
FCM4 used as an FCM3 replacement Yes FCM4 behaves as FCM3 when used within an FCM3 array
FCM4 used to extend an FCM3 RAID array Yes FCM4-specific features are unavailable to the mixed array
Dedicated FCM3 and FCM4 arrays in the same system Yes Allows an all-FCM4 array to retain FCM4-specific functionality
FCM4 Computational Storage in a mixed FCM3/FCM4 array No An all-FCM4 array is required for FCM4-specific Computational Storage functionality

FCM2 and FCM3 Compatibility

FCM2 and FCM3 do not share the same array-level compatibility available between FCM3 and FCM4.

FCM2 and FCM3 cannot coexist within the same RAID array. Changes between the generations include PCIe technology, NAND technology, compression implementation, and capacity characteristics.

Compatibility Rule: FCM1 and FCM2 form one compatible pair for applicable array-level replacement scenarios, while FCM3 and FCM4 form the next compatible pair. FCM2 and FCM3 cannot be intermixed within the same RAID array.

Hardware-Based Inline Compression

IBM FlashCore Module 3 performs inline data compression directly within the FlashCore hardware. Compressing data within the storage module increases effective capacity for compressible workloads while reducing the compression workload placed on the FlashSystem controller processors.

Benefits include:

  • Increased effective storage capacity
  • Reduced physical flash consumption
  • Minimal FlashSystem controller overhead for FlashCore compression
  • Consistent application response times
  • Improved storage density for compressible workloads

Encryption and Data Protection

The IBM ADSB FlashCore Module provides hardware-based data-protection capabilities integrated directly into the FlashCore architecture.

  • Self-encrypting storage technology
  • Hardware-based data-at-rest protection
  • T10-DIF data-integrity protection
  • Integration with IBM FlashSystem encryption and security capabilities

FCM3 vs. FCM4

FCM3 and FCM4 share common capacity points and core FlashCore capabilities, but FCM4 introduced additional Computational Storage functionality.

CapabilityFCM3FCM4
NVMe FlashCore Technology Yes Yes
Hardware-Based Compression Yes Yes
Self-Encryption Yes Yes
T10-DIF Data Protection Yes Yes
Computational Storage No Yes
FCM4-Specific Threat Detection Functions No Available with qualifying all-FCM4 configurations and supported software
FCM4 Can Replace FCM3 Not Applicable Yes

FlashCore Module 4 FCM4 Capacity and FCM3 Replacement Options

FlashSystem 7300 Feature CodeCapacityPart Numbers and FRU
IBM AHSE 4.8TB 03NK832 03JK992 03LG000 03LG009
IBM AHSF 9.6TB 03NK831 03LG001 03LG002 03JN354 03LG014
IBM AHSG 19.2TB 03NK830 03LG010 03LG015
IBM AHSH 38.4TB 03JN350 03LG019 03LG015 03LG003 03LG016

Equivalent 9.6TB FCM3 Feature Codes

IBM uses different feature codes for the 9.6TB FCM3 depending on the target FlashSystem platform.

IBM FlashSystemFeature CodeCapacityGeneration
IBM FlashSystem 5200 AGSB 9.6TB FCM3
IBM FlashSystem 7300 ADSB 9.6TB FCM3
IBM FlashSystem 9500 AHSA 9.6TB FCM3

Typical Workloads

The IBM ADSB 9.6TB FCM3 can support the broad range of enterprise workloads attached to an IBM FlashSystem 7300, including:

  • IBM i
  • AIX
  • Linux
  • IBM Power Systems workloads
  • VMware environments
  • Microsoft Hyper-V
  • Oracle Database
  • Microsoft SQL Server
  • SAP environments
  • Enterprise virtualization
  • Database workloads
  • Business-critical applications

Replacement and Expansion Considerations

Before purchasing or installing an IBM ADSB or equivalent 9.6TB FlashCore Module 3, verify:

  • The exact IBM FlashSystem model and machine type.
  • The correct machine-specific IBM feature code.
  • The FRU or replacement part number of the installed module.
  • The installed FlashCore firmware level.
  • The IBM Storage Virtualize software level.
  • The capacity and generation of modules already present in the target RAID array.
  • Whether the module will be used for replacement, array expansion, MES upgrade, or creation of a new array.
  • Whether FCM4-specific Computational Storage capabilities are required.

Administrators should verify the existing array configuration and IBM-supported hardware matrix before ordering expansion or replacement media, particularly when introducing a different FlashCore generation.

How to Identify an Installed FCM3

IBM FlashCore firmware levels provide a convenient method of identifying the installed FlashCore generation. An FCM firmware level beginning with 3_ identifies a FlashCore Module 3. FlashCore firmware, FRU, capacity, and other drive information can also be reviewed from the IBM FlashSystem management interface.

IBM ADSB 9.6TB FCM3 Summary

The IBM ADSB 9.6TB NVMe FlashCore Module 3 provides enterprise NVMe flash capacity for the IBM FlashSystem 7300 with hardware-based inline compression, self-encryption, data-integrity protection, and integration with IBM Storage Virtualize.

The ADSB feature identifies the 9.6TB FCM3 for FlashSystem 7300 systems, while equivalent 9.6TB FCM3 capacity is represented by AGSB on FlashSystem 5200 and AHSA on FlashSystem 9500 configurations.

For existing FCM3 environments, FCM4 provides a supported replacement and expansion path. An FCM4 can replace an FCM3, extend an existing FCM3 RAID array, or be introduced as new storage on supported systems. When FCM3 and FCM4 are mixed in the same RAID array, however, the FCM4 operates with FCM3-level functionality. Dedicated all-FCM4 arrays are required when FCM4-specific Computational Storage capabilities are needed.