IBM AHSB 19.2 TB 2.5 Inch NVMe Flash Core Module 3.0 for IBM FS9500
IBM AHSB 19.2TB NVMe FlashCore Module 3 FCM3
IBM Feature Code AHSB | 19.2TB NVMe FlashCore Module 3 for IBM FlashSystem an IBM FlashSystem 9500 FS9500 4666-AH8 4983-AH8
The IBM AHSB 19.2TB NVMe FlashCore Module 3 FCM3 is a third-generation IBM FlashCore storage module designed for an IBM FlashSystem 9500 FS9500 4666-AH8 and 4983-AH8 and related IBM FlashSystem platforms that support FCM3 technology. The IBM FlashCore Module 3 combines enterprise NVMe flash storage with hardware-based inline compression, self-encryption, advanced flash management, data-integrity protection, and integration with IBM Storage Virtualize. Unlike conventional enterprise NVMe SSDs, IBM FlashCore Modules incorporate IBM-developed hardware and firmware specifically optimized for IBM FlashSystem storage. The IBM FCM3 architecture provides high throughput, predictable low latency, hardware-assisted data reduction, and enterprise-class reliability while reducing the compression workload placed on the FlashSystem controller processors. The IBM AHSB feature code identifies the 19.2TB FCM3 used with the IBM FlashSystem 9500 FS9500 4666-AH8 4983-AH8. IBM FlashSystems part numbers associated with the 19.2TB FCM3 family include 03JK160, 03GH931, 03JK078, 03GH932, 03JK164, 03LG624 and 03JK699.
IBM ADSC 19.2TB NVMe FlashCore Module 3 FCM3 is for an IBM FlashSystem 7300 FS7300 4657-924 and IBM AGSC 19.2TB NVMe FlashCore Module 3 FCM3 is for IBM FlashSystem 5200 FS5200 4662-6H2. Use the email price feature from on this product page for IBM AHSB 19.2TB NVMe FlashCore Module FCM3 pricing, to request an IBM FlashSystem upgrade quote, or if you have general IBM FlashCore module compatibility questions for your specific FlashSystem model. All IBM FlashCore Modules, FlashSystem systems and parts include warranty, support and are eligibile for IBM maintenance.
IBM AHSB 19.2TB FCM3 Key Features
- IBM Feature Code: AHSB
- FlashCore Generation: FlashCore Module 3 (FCM3)
- Capacity: 19.2TB
- IBM Part Numbers: 03JK078, 03GH931, 03GH932, 03JK160, 03JK164, 03JK699, 03LG624
- Enterprise NVMe storage architecture
- Hardware-based inline data compression
- Self-encrypting FlashCore technology
- Hardware-based data-at-rest protection
- T10-DIF data-integrity protection
- IBM advanced flash management
- Enterprise-class endurance and reliability
- Designed for IBM Storage Virtualize environments
- Compatible with FCM4 replacement and expansion scenarios on supported systems
Technical Specifications
| IBM Feature Code | AHSB |
|---|---|
| FlashCore Generation | FlashCore Module 3 (FCM3) |
| Capacity | 19.2TB |
| Logical / Effective Capacity | Up to 57.6TB based on IBM's published FCM logical-capacity specification |
| IBM Part Numbers | 03JK078, 03GH931, 03GH932, 03JK160, 03JK164, 03JK699, 03LG624 |
| Storage Interface | NVMe |
| Compression | Hardware-based inline compression |
| Encryption | Self-encrypting FlashCore technology |
| Data Integrity | T10-DIF support |
| Computational Storage | No, computational-storage-assisted ransomware detection was introduced with FCM4 |
| FCM4 Compatibility | FCM4 may be used as a replacement, MES upgrade, array extension, or additional storage on supported FCM3 systems |
IBM FlashSystem Compatibility
The AHSB feature code identifies the 19.2TB FlashCore Module 3 for the IBM FlashSystem 9500 FS9500 4666-AH8 4983-AH8. The same 19.2TB FCM3 technology is supported by other FCM3-capable IBM FlashSystem platforms under different machine-specific feature codes.
| IBM FlashSystem Model | FCM3 Support | 19.2TB FCM3 Feature Code |
|---|---|---|
| IBM FlashSystem 5200 | FS5200 4662-6H2 | AGSC |
| IBM FlashSystem 7300 | FS7300 4657-924 | ADSC |
| IBM FlashSystem 9500 | FS9500 4666-AH8 4983-AH8 | AHSB |
FCM3 and FCM4 Compatibility
IBM FlashCore Module 4 was designed as a compatible replacement and expansion path for FlashCore Module 3. On supported IBM FlashSystem 5200, 7300, and 9500 systems, FCM4 modules can be used to replace FCM3 modules, extend an existing FCM3 RAID array, provide additional storage, or be introduced as part of an MES upgrade. This compatibility is particularly useful for existing FCM3 installations because an organization does not need to replace every FCM3 in the system simply because an FCM3 requires replacement or additional capacity is needed.
Can FCM3 and FCM4 Be Installed in the Same FlashSystem?
Yes. FCM3 and FCM4 can coexist within supported IBM FlashSystem 5200, 7300, and 9500 systems. Supported configurations can include:
- Existing FCM3 arrays remaining in service while new FCM4 storage is added.
- An FCM4 replacing an FCM3 module as a supported service replacement.
- FCM4 modules being used to extend an existing FCM3 RAID array.
- Dedicated all-FCM4 arrays operating alongside existing FCM3 arrays.
- A phased transition from FCM3 to FCM4 rather than replacing all storage modules simultaneously.
Can FCM3 and FCM4 Be Mixed in the Same RAID Array?
Yes. FCM4 is designed to operate as a replacement or extension within supported FCM3 RAID arrays. There is, however, an important difference between simply operating an FCM4 and obtaining the additional functionality introduced by FCM4:
Administrators who need FCM4 Computational Storage capabilities should create a RAID array composed entirely of FCM4 modules. IBM requires all-FCM4 arrays and the applicable IBM Storage Virtualize software level for FCM4 computational-storage-assisted ransomware threat detection.
FCM3 / FCM4 Compatibility Summary
| Configuration | Supported | Operational Consideration |
|---|---|---|
| FCM3 and FCM4 in the same FlashSystem | Yes | Supported on applicable FlashSystem 5200, 7300, and 9500 systems |
| FCM4 used as an FCM3 replacement | Yes | FCM4 functions with FCM3-level capabilities when installed in an FCM3 array |
| FCM4 used to extend an FCM3 RAID array | Yes | FCM4-specific Computational Storage functionality is unavailable to the mixed array |
| Dedicated FCM3 and FCM4 arrays in the same system | Yes | Allows the all-FCM4 array to retain FCM4-specific capabilities |
| FCM4 Computational Storage in a mixed FCM3/FCM4 array | No | An all-FCM4 RAID array is required |
| FCM4 ransomware threat-detection assist | All-FCM4 array required | Array must meet the applicable IBM Storage Virtualize software requirement |
FCM4 Computational Storage Requirements
One of the significant differences between FCM3 and FCM4 is the addition of Computational Storage capabilities in FlashCore Module 4. FCM4 can assist IBM Storage Virtualize with real-time ransomware threat detection by analyzing storage activity within the FlashCore hardware. To use this FCM4 functionality, IBM requires:
- A RAID array composed entirely of FCM4 modules.
- The array to be created using a supported IBM Storage Virtualize software level.
- IBM Storage Virtualize 8.6.2 or later for the applicable FCM4 computational-storage-assisted threat-detection functionality.
An FCM4 installed as a replacement for an AHSB or another FCM3 within an existing FCM3 array will provide storage functionality, but the mixed array will continue to operate with FCM3-level capabilities.
FCM2 and FCM3 Compatibility
FCM2 and FCM3 have different compatibility rules than the compatible FCM3 and FCM4 generation pair. FCM2 and FCM3 cannot be intermixed within the same RAID array. Hardware and architectural changes between the generations include changes to PCIe technology, NAND technology, compression implementation, and capacity characteristics.
Hardware-Based Inline Compression
IBM FlashCore Module 3 performs inline data compression within the FlashCore hardware rather than requiring the FlashSystem controller processors to perform the primary FlashCore compression workload. The technology allows compressible data to consume less physical flash capacity while maintaining the performance characteristics expected from an enterprise NVMe storage system. Benefits include:
- Increased effective storage capacity
- Reduced physical flash consumption
- Hardware-assisted data reduction
- Reduced compression overhead on FlashSystem controller processors
- Consistent application response times
- Improved storage density for compressible workloads
19.2TB Capacity and Effective Capacity
The AHSB provides 19.2TB of physical FlashCore capacity. IBM publishes a logical capacity of up to 57.6TB for the 19.2TB FCM3 capacity point based on its stated data-reduction assumptions.
| Physical FCM Capacity | 19.2TB |
|---|---|
| IBM Published Logical Capacity | 57.6TB |
| Actual Effective Capacity | Varies according to workload and achievable data-reduction ratio |
Encryption and Data Protection
The IBM AGSC FlashCore Module incorporates hardware-based data-protection capabilities directly within the FlashCore architecture.
- Self-encrypting storage technology
- Hardware-based encryption for data at rest
- T10-DIF data-integrity protection
- Integration with IBM FlashSystem security and encryption capabilities
FCM3 vs. FCM4
FCM3 and FCM4 provide the same principal 4.8TB, 9.6TB, 19.2TB, and 38.4TB capacity points, but FCM4 introduces additional capabilities through its Computational Storage architecture.
| Capability | FCM3 | FCM4 |
|---|---|---|
| NVMe FlashCore Technology | Yes | Yes |
| 19.2TB Capacity | Yes | Yes |
| Hardware-Based Compression | Yes | Yes |
| Self-Encryption | Yes | Yes |
| T10-DIF Data Protection | Yes | Yes |
| Computational Storage | No | Yes |
| Hardware-Assisted Ransomware Threat Detection | No | Yes, with qualifying all-FCM4 arrays and supported software |
| FCM4 Can Replace FCM3 | Not Applicable | Yes |
FlashCore Module 3 Capacity Reference
| FlashSystem 9500 Feature Code | Capacity | Part Numbers |
|---|---|---|
| AHS9 | 4.8TB | 03JK076 03JK162 03GH935 03GH936 03JK687 |
| AHSA | 9.6TB | 03JK077 03JK163 03JL077 03JK693 03GH933 03JK077 03LG627 |
| AHSB | 19.2TB | 03JK164 03GH931 03GH932 03JK078 03JK160 03JK699 03LG624 |
| AHSC | 38.4TB | 03JK079 03JK165 03GH929 |
Equivalent 19.2TB FCM3 Feature Codes
IBM uses different feature codes for the 19.2TB FCM3 depending on the target FlashSystem platform.
| IBM FlashSystem | Feature Code | Capacity | Generation |
|---|---|---|---|
| IBM FlashSystem 5200 | AGSC | 19.2TB | FCM3 |
| IBM FlashSystem 7300 | ADSC | 19.2TB | FCM3 |
| IBM FlashSystem 9500 | AHSB | 19.2TB | FCM3 |
Typical Workloads
The IBM AHSB 19.2TB FCM3 supports the broad range of enterprise workloads that can be hosted on or connected to an IBM FlashSystem 9500 FS9500 4666-AH8 4983-AH8, including:
- IBM i
- AIX
- Linux
- IBM Power Systems workloads
- VMware environments
- Microsoft Hyper-V
- Oracle Database
- Microsoft SQL Server
- SAP environments
- Enterprise virtualization
- Database workloads
- High-capacity production storage
- Business-critical applications
Replacement and Expansion Considerations
Before purchasing or installing an IBM AHSB or equivalent 19.2TB FlashCore Module 3, verify:
- The exact IBM FlashSystem model and machine type.
- The correct machine-specific IBM feature code.
- The FRU or replacement part number of the installed FlashCore Module.
- The installed FlashCore firmware level.
- The IBM Storage Virtualize software level.
- The capacity and FlashCore generation of modules already present in the target RAID array.
- Whether the module will be used as a replacement, array expansion, MES upgrade, or new array.
- Whether FCM4-specific Computational Storage functionality is required.
Part-number verification is especially important when replacing FlashCore media because multiple IBM part numbers can correspond to the same capacity and FlashCore generation. Verify the target machine type, existing hardware, and supported replacement before ordering a module.
How to Identify an Installed FCM3
The FlashCore firmware level provides a convenient method of identifying the installed FlashCore generation. FlashCore firmware beginning with 3_ identifies a FlashCore Module 3. For example: Firmware Level: 3_1_11
The first digit identifies the FlashCore generation, making this an FCM3. The IBM FlashSystem management interface can also be used to review drive properties such as capacity, firmware level, FRU part number, drive state, endurance information, and RAID membership.
IBM AHSB 19.2TB FCM3 Summary
The IBM AHSB 19.2TB NVMe FlashCore Module 3 provides high-capacity enterprise NVMe storage for the IBM FlashSystem 9500 FS9500 4666-AH8 4983-AH8 with hardware-based inline compression, self-encryption, data-integrity protection, and integration with IBM Storage Virtualize. The AHSB feature identifies the 19.2TB FCM3 for the FlashSystem 9500, while equivalent 19.2TB FCM3 capacity is represented by AGSC on the FlashSystem 5200 and ADSC on the FlashSystem 7300.
IBM FCM4 provides a supported replacement and expansion path for existing FCM3 environments. An FCM4 can replace an FCM3, extend an existing FCM3 RAID array, or be introduced as additional storage on supported systems. When FCM3 and FCM4 are mixed in the same RAID array, however, the FCM4 operates with FCM3-level functionality. Organizations requiring FCM4-specific Computational Storage and hardware-assisted ransomware threat detection should use dedicated RAID arrays composed entirely of FCM4 modules and meet the applicable IBM Storage Virtualize software requirements.